Liquid Flow Meters / Controllers
Liquid Flow Meters
Liquid mass flow meters of the µ-FLOW series are built around a stainless steel tube without any moving parts or obstructions. The heater/sensor assembly is arranged around the tube and a constant power is applied to warm up the liquid inside the tube. Flowing liquid results in shift of the temperature difference (ΔT) which is proportional to the mass flow. Due to the benefits of the applied sensor, the fluid will be warmed to a maximum of 5°C, thereby making the µ-FLOW Series suitable for fluids with low boiling points.
Liquid Flow Controllers
Flow control is achieved by integrating a control valve onto the body of the Liquid Flow Meter. This control valve has a purge connection to eliminate air or gas during start-up. The electronic control function forms part of the normal circuitry in the meter.