Bronkhorst

MAG-VIEW MVM-002-PN

Low-Flow Magnetic Inductive Flow meters for water-like liquids

  • Compact, weatherproof (IP65) design
  • No moving parts (no mechanical wear)
  • Interference free operation
  • Independence to inlet/outlet pipework
  • Fast response
  • Free pipe cross section: low ΔP, insensitive to contamination
  • Pulse output
MASSFLOW-ONLINE product
  Vraag offerte aan Downloads Koop nu Datasheet
MAG-VIEWMVM-002-PN

Electromagnetic flow meters for low flow rates of water and aqueous solutions

MAG-VIEW instruments are electromagnetic inductive flow meters for electrically conductive liquids with a minimum conductivity of 50 μS/cm. The compact, weatherproof (IP65) flow meters do not contain any moving parts, cause virtually no pressure loss and can be mounted in any position, requiring no straight inlet or outlet runs.

MAG-VIEW flow meter model MVM-002-PN has a nominal diameter of DN2 for flow rates of 0,05...2 l/min, suited for operating pressures up to 16 bar(g). The pulse output of the instrument is proportional to the flow.


Technische specificaties

Meet- / regelsysteem
Flow0,05 … 2 l/min
Nauwkeurigheid volumeflowmeting±1% RD at 0...50% of measuring range
±2% RD at 50...100% of measuring range
(incl. factory calibration certificate; test conditions: water 23°C)
Turndown ratio1:40
reproduceerbaarheid1 % FS
Signaaluitgang vanaf~ 0,05 l/min
MediaWater and other conductive liquids
(minimum conductivity of 50 μS/cm)
Responstijd (sensor)< 500 msec
Gemiddelde temperatuur-20 … 90 °C
MontageAny position, attitude insensitive
Flow indicatiegreen LED, flow proportional flashing
Mechanische delen
Materiaal (onderdelen die in contact komen met het medium)Electrodes: Stainless Steel 1.4571
Process connections: Stainless Steel 1.4571
Measuring pipe: PEEK-GF30
Gasket: EPDM
BehuizingAluminium pressure diecasted
DiameterDN2
Procesaansluitingen1/4" BSP male thread
Beschermingsgraad (behuizing)IP65
Nominale drukPN16
Elektrische eigenschappen
Stroomvoorziening24 Vdc ±10 %
Max. stroomverbruik150 mA
Frequentie uitgangPulse rate / K-factor : 10000 pulses/l
Resolution : 0,1 ml/pulse
Signal shape : Square wave signal - duty cycle 50:50
Push-Pull - NPN open collector [o.c.] - PNP o.c.
Signal current : max. 100 mA, current limited
Elektrische beveiligingsmaatregelenShort-circuit proof, protected against polarity reversal
Elektrische aansluiting5-pin-plug M12x1
Elektrische aansluiting
Control valve options
Externe actuatoropties die op de controller moeten worden aangesloten
Certificering voor explosiegevaarlijke zones
Goedkeuringen / certificaten

Technische specificaties kunnen zonder kennisgeving worden gewijzigd.

Voor technische maattekeningen en aansluitschema's bezoekt u de productpagina op onze website

Downloads

Brochures
MAG-VIEW Brochure