我們提供市場上最全面的低流量質量流量計產品系列。 可以為實驗室、機械、工業和危險區域的應用提供多種類型的標準和定制儀器。
客戶滿意度、創新以及產品和服務質量一直是 Bronkhorst 成功的基石。 基於我們的經驗、創新和責任感,Bronkhorst 爲您確保了 Performance for Life。
Bronkhorst 儀器用於許多不同市場的眾多應用。 在這裏您將找到我們設備的主要市場概覽,並附有一些典型應用案例。
您是在尋找技術文檔,還是想了解更多關於 Bronkhorst 產品測量原理的資訊,或者您想聯繫 Bronkhorst 的服務工程師? 在這裏您將找到相關的服務和支援主題。
Bronkhorst High-Tech BV 是在氣體和液體,壓力控制器和蒸發系統方面質量流量計/質量流量控制器技術的領導者。
The National Aeronautics and Space Administration (NASA) recently redesigned the system used to test the new space suit Portable Life Support System (PLSS) that is under development. In order to test the PLSS a simulated human metabolic load must be applied to the various sub-systems and so NASA needed to simulate the human production of CO2 and water vapor with its associated heat load. Working closely with NASA engineers to fully understand the application requirements, Bronkhorst learned that accurate, stable control of water vapor was critical to efficient and repeatable testing and therefore successful development of the PLSS.
The recommended Bronkhorst solution was a Controlled Evaporation Mixing (CEM) system to properly control the mass of water being vaporized as well as the amount of CO2 in the vapor. NASA has three CEM systems connected to an outlet manifold. Each CEM system consists of a liquid mass flow controller (H2O), a gas mass flow controller (CO2), a Controlled Evaporator Mixer, and a readout/control unit. The three connected CEM systems are collectively referred to as the Human Metabolic Simulator (HMS). The Bronkhorst HMS equipment is controlled via analog (0-5 Vdc) signals through the Bronkhorst readout/control units (1 per CEM system) which in turn are connected to the NASA main test system running NASA’s customized LabVIEW software. This setup allows NASA to simulate those aspects of human metabolic output up to a rate of ~3500 BTU/hr, or a bit over 1000 Watts, by injecting the CO2/water vapor mix into a simulated spacesuit volume containing a manikin (“Manny”) which is wearing a Liquid Cooling and Ventilation Garment (LCVG). The LCVG removes sensible heat to keep the human core temp in nominal range, and also provides some latent heat removal via condensation of human-generated water vapor on the surface of the cooling tubes. To complete the human metabolic load simulation, NASA has placed controllable heaters on the CO2/H2O vapor deliver lines to prevent condensation and to add super-heat as needed. Additionally, they have controllable electric heaters on the manikin body to simulate sensible heat generation by a human being working at various levels of effort. There is also a Bronkhorst mass flow controller to remove gas from the suit at rates that simulate metabolic consumption of suit gas as well as suit leakage.