EX-FLOW F-202AX

가스용 방폭 질량 흐름 컨트롤러

  • ATEX 승인 Cat.2, Zone 1
  • 높은 정확도, 높은 재연성
  • 압력 및 온도와 거의 무관함
  • 컴팩트한 디자인
Get a quote 다운로드 Datasheet
EX-FLOWF-202AX

Intrinsically Safe Gas Mass Flow Controllers for medium flow rates

Bronkhorst® EX-FLOW Mass Flow Controllers (MFCs) are suited for precise gas flow control in ATEX Zone 1 hazardous areas. The flow meter part and the control valve of the MFC should be connected (via separate cables) to a power supply with galvanic isolation / preamplifier / readout system (located in the safe zone) which contains a controller board to complete the control loop. See Bronkhorst® E-8000 Series.

EX-FLOW model F-202AX covers flow ranges from 0,6...30 ln/min up to 5...250 ln/min (N2-equivalent) at operating pressures up to 64 bar.

The intrinsically safe measuring head of the flow meter is tested according to ATEX 114 Directive 2014/34/EU and approved under EC-Type Examination Number: KEMA 01ATEX1172, protection II 2 G Ex ib IIC T4 Gb.
The intrinsically safe valve coils are explosion proof certified and available in two options (ATEX certification only):
Coil XB: protection II 1 G Ex ia IIC T6 / protection II 1 D Ex ta IIIC T80°C
Coil XC: protection II 2 G Ex eb IIC T4 / protection II 2 D Ex tb IIIC T130°C


기술 정보

Measurement / control system
Flow range (intermediate ranges available)min. 0,6…30 ln/min
max. 5…250 ln/min
(based on N2)
정확도 (선형도) (실제 검교정 기반)± 1 % FS
Repeatability< 0,2 % RD
Turndown ratio1:50 (2…100%)
Time constant5 sec.
Control stability≤ ± 0,1 % FS typical
Operating temperature-10 … +65 °C
Temperature sensitivityzero: < 0,05% FS/°C; span: < 0,05% Rd/°C
Max. Kv-value0,04 … 0,4
Leak integrity, outboardtested < 2 x 10-9 mbar l/s He
Attitude sensitivitymax. error at 90° off horizontal 0,2% FS at 1 bar, typical N2
Warm-up time30 min. for optimum accuracy
2 min. for accuracy ± 2% FS
Mechanical parts
Material (wetted parts)Stainless steel 316L or comparable
Pressure rating (PN)64 bar abs
Max. ΔP20 bar(d)
Process connectionscompression type or face seal (VCR/VCO) couplings
Sealsstandard: FKM/Viton®;
options: EPDM, FFKM/Kalrez®, FDA and USP Class VI approved compounds
Ingress protectionIP65
Electrical properties
Output signal15 … 20 mA (linear)
Terminal connection, cable gland M16x1,5
I/O signals via PS/Readout (located in safe area)analog: 0…5 Vdc, 0…10 Vdc, 0…20 mA, 4…20 mA;
digital: RS232, PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, PROFINET, EtherCAT®, FLOW- BUS
XB-coilCoil voltage max. 28 V/110 mA;
295 Ohm at 20°C
XC-coilCoil voltage max. 24 V;
65 Ohm at 20°C, Pmax = 9 W at 20°C
Electrical connection
Ex-proof measuring headTerminal connection, cable gland M16x1,5
Control valve coilcable gland M20x1,5
Control valve options
External actuator options to be connected to the controller
Certification for hazardous areas
Approvals / certificates

Technical specifications subject to change without notice.

도면 및 배선연결 정보 제품 페이지 우리의 웹사이트

Downloads

Brochures
EX-FLOW brochure
Manuals
Manual EX-FLOW meters and controllers - ATEX
Manual EX-FLOW meters and controllers - IECEx
Manual EX-FLOW meters and controllers - TIIS
Hook-up diagram
MFM Measuring Head
XB-Coil
XC-Coil
Dimensional drawing
Dimensional drawing F-202AX-F-212AX
Certificates
IECEx Certificate EX-FLOW MFM Measuring Head X100 : IECEx DEK14.0060
TIIS Certificate EX-FLOW MFM Measuring head X100 : 検・第TC21584号 (Japanese certification)
KCs Certificate EX-FLOW MFM Measuring Head X100 :: Ex ib IIC T4 (Korean certification)
ATEX CAT 2 Certificate EX-FLOW MFM Measuring Head X100 : KEMA 01ATEX1172
EU Declaration of Conformity Measuring Head X100 : ATEX CAT 2 (doc. 9.06.032)
ATEX CAT 2 Certificate XB-coil
ATEX CAT 2 Certificate XC-coil
ATEX CAT 2 Notification Directive 2014/34/EU : DEKRA 12ATEXQ0100


BRONKHORST KOREA Co. Ltd

경기도 화성시 동탄순환대로 830 SK
V1 Center 209호
대표자 : 헨드리크제지너스타펠
사업자등록번호 : 119-86-74469

           Social Responsibility
Copyright © 2024 Bronkhorst. All rights reserved.     Sitemap     Disclaimer     Privacy note