Bronkhorst

EX-FLOW F-206BX

Ex-Protected Mass Flow Controller for High Gas Flow

  • ATEX approval Cat.2, Zone 1
  • High accuracy, excellent repeatability
  • Virtually pressure and temperature independent
  • Compact design
Get a quote Downloads Datasheet
EX-FLOWF-206BX

Intrinsically Safe Gas Mass Flow Controllers for high flow rates

Bronkhorst® EX-FLOW Mass Flow Controllers (MFCs) are suited for precise gas flow control in ATEX Zone 1 hazardous areas. The flow meter part and the control valve of the MFC should be connected (via separate cables) to a power supply with galvanic isolation / preamplifier / readout system (located in the safe zone) which contains a controller board to complete the control loop. See Bronkhorst® E-8000 Series.

EX-FLOW model F-206BX covers flow ranges from 1...50 m3n/h up to 7,5…375 m3n/h (N2-equivalent) at operating pressures up to 64 bar.

The intrinsically safe measuring head of the flow meter is tested according to ATEX 114 Directive 2014/34/EU and approved under EC-Type Examination Number: KEMA 01ATEX1172, protection II 2 G Ex ib IIC T4 Gb.
The intrinsically safe valve coils are explosion proof certified and available in two options (ATEX certification only):
Coil XB: protection II 1 G Ex ia IIC T6 / protection II 1 D Ex ta IIIC T80°C
Coil XC: protection II 2 G Ex eb IIC T4 / protection II 2 D Ex tb IIIC T130°C


Technical specifications

Measurement / control system
Flow range (intermediate ranges available)min. 1…50 m3n/h
max. 7,5…375 m3n/h
(based on N2)
Accuracy (incl. linearity) (based on actual calibration)± 1 % FS
Repeatability< 0,2 % RD
Turndown ratio1:50 (2…100%)
Time constant5 sec.
Control stability≤ ± 1 % FS typical
Operating temperature-10 … +65 °C
Temperature sensitivityzero: < 0,05% FS/°C; span: < 0,05% Rd/°C
Max. Kv-value0,6 … 6
Leak integrity, outboardtested < 2 x 10-9 mbar l/s He
Attitude sensitivitymax. error at 90° off horizontal 0,2% FS at 1 bar, typical N2
Warm-up time30 min. for optimum accuracy
2 min. for accuracy ± 2% FS
Mechanical parts
Material (wetted parts)Stainless steel 316L or comparable
Pressure rating (PN)64 bar abs
Max. ΔP20 bar(d)
Process connectionscompression type or face seal (VCR/VCO) couplings
Sealsstandard: FKM/Viton®;
options: EPDM, FFKM/Kalrez®
Ingress protectionIP65
Electrical properties
Output signal15 … 20 mA (linear)
Terminal connection, cable gland M16x1,5
I/O signals via PS/Readout (located in safe area)analog: 0…5 Vdc, 0…10 Vdc, 0…20 mA, 4…20 mA;
digital: RS232, PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, PROFINET, EtherCAT®, FLOW- BUS
XB-coilCoil voltage max. 28 V/110 mA;
295 Ohm at 20°C
XC-coilCoil voltage max. 24 V;
65 Ohm at 20°C, Pmax = 9 W at 20°C
Electrical connection
Ex-proof measuring headTerminal connection, cable gland M16x1,5
Control valve coilcable gland M20x1,5
Control valve options
External actuator options to be connected to the controller
Certification for hazardous areas
Approvals / certificates

Technical specifications subject to change without notice.

For dimensional drawings and hook-up diagrams please visit the product page on our website

Downloads

Brochures
EX-FLOW brochure
Manuals
Manual EX-FLOW meters and controllers - ATEX
Manual EX-FLOW meters and controllers - IECEx
Manual EX-FLOW meters and controllers - TIIS
Hook-up diagram
MFM Measuring Head
XB-Coil
XC-Coil
Dimensional drawing
Dimensional drawing F-206BX-F-216BX