Bronkhorst

EX-FLOW F-131MX

High-Pressure Mass Flow Meter for Gases, Ex-proof Style

  • ATEX approval Cat.2, Zone 1
  • Also IECEx, TIIS and KCs certified
  • High accuracy, excellent repeatability
  • Virtually pressure and temperature independent
  • Pressure rating 400 bar
Get a quote Downloads Datasheet
EX-FLOWF-131MX

Intrinsically Safe Gas Mass Flow Meters for low flow rates

Bronkhorst® EX-FLOW Mass Flow Meters (MFMs) are suited for precise gas flow measurement in ATEX Zone 1 hazardous areas. The MFM should be connected to a power supply with galvanic isolation / preamplifier / readout system (located in the safe zone). See Bronkhorst® E-8000 Series.

EX-FLOW model F-131MX covers flow ranges from 0,3...15 mln/min up to 0,4...20 ln/min (N2-equivalent) at operating pressures up to 400 bar.

The intrinsically safe measuring head of the flow meter is tested according to ATEX 114 Directive 2014/34/EU and approved under EC-Type Examination Number: KEMA 01ATEX1172, protection II 2 G Ex ib IIC T4 Gb.
Other certifications: IECEx (IECEx DEK14.0060) and TIIS (検・第TC21584号).


Technical specifications

Measurement / control system
Flow range (intermediate ranges available)min. 0,3…15 mln/min
min. 0,4…20 mln/min
(based on N2)
Accuracy (incl. linearity) (based on actual calibration)± 1 % FS
Repeatability< 0,2 % RD
Turndown ratio1 : 50 (in digital mode up to 1 : 150)
Time constant5 sec.
Operating temperature-10 … +70 °C
Temperature sensitivityzero: < 0.05% FS/°C; span: < 0.05% Rd/°C
Leak integrity, outboardtested < 2 x 10-9 mbar l/s He
Attitude sensitivitymax. error at 90° off horizontal 0,2% FS at 1 bar, typical N2
Warm-up time30 min. for optimum accuracy
2 min. for accuracy ± 2% FS
Mechanical parts
Material (wetted parts)Stainless steel 316L or comparable
Pressure rating (PN)400 bar abs
Process connectionscompression type or face seal (VCR/VCO) couplings
Sealsstandard: FKM/Viton®;
options: EPDM, FFKM/Kalrez®
Ingress protectionIP65
Electrical properties
Output signal15 … 20 mA (linear)
Terminal connection, cable gland M16x1,5
I/O signals via PS/Readout (located in safe area)analog: 0…5 Vdc, 0…10 Vdc, 0…20 mA, 4…20 mA;
digital: RS232, PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, PROFINET, EtherCAT®, FLOW-BUS
Electrical connection
Ex-proof measuring headTerminal connection, cable gland M16x1,5
Control valve options
External actuator options to be connected to the controller
Certification for hazardous areas
Approvals / certificates

Technical specifications subject to change without notice.

For dimensional drawings and hook-up diagrams please visit the product page on our website

Downloads

Brochures
EX-FLOW brochure
Manuals
Manual EX-FLOW meters and controllers - ATEX
Manual EX-FLOW meters and controllers - IECEx
Manual EX-FLOW meters and controllers - TIIS
Hook-up diagram
MFM Measuring Head
XB-Coil
XC-Coil
Dimensional drawing
Dimensional drawing F-121MX-F-131MX
Certificates
IECEx Certificate EX-FLOW MFM Measuring Head X100 : IECEx DEK14.0060
TIIS Certificate EX-FLOW MFM Measuring head X100 : 検・第TC21584号 (Japanese certification)
KCs Certificate EX-FLOW MFM Measuring Head X100 :: Ex ib IIC T4 (Korean certification)
ATEX CAT 2 Certificate EX-FLOW MFM Measuring Head X100 : KEMA 01ATEX1172
EU Declaration of Conformity Measuring Head X100 : ATEX CAT 2 (doc. 9.06.032)
ATEX CAT 2 Certificate XB-coil
ATEX CAT 2 Certificate XC-coil
ATEX CAT 2 Notification Directive 2014/34/EU : DEKRA 12ATEXQ0100


BRONKHORST (UK) Ltd

1 Kings Court
Willie Snaith Road
Newmarket Suffolk CB8 7TG
Tel. +44 1223 833222
[email protected]

         Social Responsibility
Copyright © 2024 Bronkhorst. All rights reserved.     Sitemap     Disclaimer     Privacy note